Combined Shape
Combined Shape

products

VSH Super reduced corner T-piece (3 x compression)

group: S1236

The VSH Super S1236 is a corner T-piece reduced with 3 compression ends. VSH Super provides a large assortment of fittings for every application, designed for optimum installation convenience. Easy installation and high quality are the top priorities of the VSH Super product range.

  • multiple tube types on one fitting (Copper, Stainless & Carbon tube)
  • same fitting applications for water and gas
  • simple installation with standard tools
  • quick connection technology allowing reassembly
read more
read less
if the download did not start automatically, click here

PDF generation failed, please try again later

applications

potable water

potable water

natural gas

natural gas

heating

heating

compressed air

compressed air

solar energy

solar energy

segments

residential

residential

commercial building

commercial building

industry

industry

approvals

DVGW Gas

DVGW Gas

DVGW Wasser

DVGW Wasser

KIWA

KIWA

VA (ETA)

VA (ETA)

item number

size

d1

DN1

l1

z1

slw1

d2

DN2

l2

z2

slw2

d3

DN3

l3

z3

item number

0871365

size

22x15x15

d1

22.0

DN1

DN20

l1

38

z1

16

slw1

32

d2

15.0

DN2

DN12

l2

38

z2

16

slw2

24

d3

15.0

DN3

DN12

l3

34

z3

10

item number

0875897

size

22x15x15 Ni

d1

22.0

DN1

DN20

l1

38

z1

16

slw1

32

d2

15.0

DN2

DN12

l2

38

z2

16

slw2

24

d3

15.0

DN3

DN12

l3

34

z3

10

item number

0871343

size

22x22x15

d1

22.0

DN1

DN20

l1

38

z1

14

slw1

32

d2

15.0

DN2

DN12

l2

38

z2

14

slw2

24

d3

22.0

DN3

DN20

l3

38

z3

16

item number

0875875

size

22x22x15 Ni

d1

22.0

DN1

DN20

l1

38

z1

14

slw1

32

d2

15.0

DN2

DN12

l2

38

z2

14

slw2

24

d3

22.0

DN3

DN20

l3

38

z3

16

technical drawing for product

characteristics

color

brass, silver

materials

brass (CW617N)

finishing

nickel-plated, none

shape

T-piece, reducer (90º)

connection type

compression, Compression

sealing

Brass

general

product group

fittings

ETIM class

EC003025 Fitting with 3 connections

HS code

74122000

brand

VSH

series

Super

type

S1236

SCIP

1e5d1bf2-d72d-4b8f-ba91-73f637c5ac6d

technical

max operating pressure liquid

10 bar

min. medium temperature

-35 °C

max medium temperature

200 °C

peak medium temperature

250 °C

image for Diagram

diagram | png

Diagram

image for S1236_group

image | png

S1236_group

certifications | pdf

EPD VSH Super Brass

link to sheet | pdf

MSDS_VSH_Super

image for S1236

image | png

S1236

image for S1236_Chroom

image | png

S1236_Chroom

certifications | pdf

VSH Super DVGW Gas

certifications | pdf

VSH Super DVGW Water

certifications | pdf

VSH Super KIWA Water 10-54 mm

certifications | pdf

VSH Super Knel water 15-54 mm ETA

certifications | pdf

VSH Super PEX ETA 10-22 mm water

installation- & maintenance document | pdf

VSH_Super_Knel_instructie_NL

label

value

label

Material connection 1

value

Brass

label

Material quality connection 1

value

CuZn40Pb2 (CW617N)

label

Material connection 2

value

Brass

label

Material quality connection 2

value

CuZn40Pb2 (CW617N)

label

Material connection 3

value

Brass

label

Material quality connection 3

value

CuZn40Pb2 (CW617N)

label

Model

value

T-piece

label

Angle

value

90°

label

Reducing

value

Yes

label

Multi-part

value

No

label

System specific

value

Yes

label

Nominal diameter connection 1

value

DN 20

label

Outer pipe diameter connection 1

value

22mm

label

Outer pipe diameter connection 1 (imperial)

value

0.87"

label

Connection 1

value

Compression ring

label

Nominal diameter connection 2

value

DN 12

label

Outer pipe diameter connection 2

value

15mm

label

Outer pipe diameter connection 2 (imperial)

value

0.59"

label

Connection 2

value

Compression ring

label

Connection 3

value

Compression ring

label

Flange compression class

value

PN 10

label

Material sealing

value

Brass

label

Length of connection 1

value

38mm

label

Length of connection 1 (imperial)

value

1.5"

label

High tensile strength

value

Yes

label

Length of connection 2

value

38mm

label

Length of connection 2 (imperial)

value

1.5"

label

Max. operating pressure at 20 °C

value

10bar

label

Max. operating pressure at 20 °C (imperial)

value

145.04psi

label

Wrench width union nut

value

32mm

label

Wrench width union nut (imperial)

value

1.26"

label

Medium temperature (continuous)

value

-35°C - 200°C

label

Medium temperature (continuous) (imperial)

value

-31°F - 392°F

label

With sealing rings/gaskets

value

No

label

With drain valve

value

No

label

With de-aerator

value

No

label

With buffer stud

value

Yes

label

Capped

value

No

label

With connection indicator

value

No

label

FM quality mark

value

No

label

LPCB quality mark

value

No

label

ULC quality mark

value

No

label

UL quality mark

value

No

label

VdS quality mark

value

No

label

Gastec QA mark

value

No

label

KOMO certified

value

No

label

Gastec QA - AR 214 (H2)

value

No

item number

carbon footprint (A1-A3) cradle-to-gate

carbon footprint (A-C) embodied carbon

carbon footprint (A-D) cradle-to-cradle

data source

item number

0871365

carbon footprint (A1-A3) cradle-to-gate

1.24kgCO2e

carbon footprint (A-C) embodied carbon

0.92kgCO2e

carbon footprint (A-D) cradle-to-cradle

0.84kgCO2e

data source

EPD

item number

0875897

carbon footprint (A-C) embodied carbon

0.87kgCO2e

data source

TM65

item number

0871343

carbon footprint (A1-A3) cradle-to-gate

1.39kgCO2e

carbon footprint (A-C) embodied carbon

1.03kgCO2e

carbon footprint (A-D) cradle-to-cradle

0.94kgCO2e

data source

EPD

item number

0875875

carbon footprint (A-C) embodied carbon

0.97kgCO2e

data source

TM65

have any questions?

feel free to contact us

product selected products selected

you can compare up to 2 products

you can compare up to 4 products

[saving downloads] requires an account

requires an account

send by email

optional
optional
This field is for validation purposes and should be left unchanged.